Installation instructions for the
T 9820 Gas Dryer
The T 9820 gas dryer is only
approved for use in the USA
and Canada. It is not approved
for use in Mexico.
en - US, CA
To prevent accidents
and machine damage
read these instructions
before
installation or use.
M.-Nr. 07 268 180
,WARNING
For your safety the information in this manual
must be followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
ß Do not try to light any appliance.
ß Do not touch any electrical switch.
ß Do not use any phone in your building.
ß Clear the room, building or area
of all occupants.
ß Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
ß If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
(In Massachusetts a licensed plumber / gas fitter.)
3
Contents
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Transporting the dryer to the installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Level the dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
How to calculate the effective duct length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Exhaust connection with a flexible exhaust hose or rigid pipe . . . . . . . . . . . . . . . 22
Direct wall connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4
IMPORTANT SAFETY INSTRUCTIONS
Installation and connection
WARNING – Improper connection of
~
the equipment grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician if you
are in doubt as to whether the
When using your gas appliance
follow basic safety precautions
including the following:
appliance is properly grounded.
Installation, repair and maintenance
~
Do not modify the plug provided
~
work should be performed by a
qualified installer, service agency or the
gas supplier. Work by unqualified
persons could be dangerous and could
void the warranty.
with the appliance! If it will not fit the
outlet, have a proper outlet installed by
a qualified electrician.
Do not use an extension cord to
~
connect this appliance to the power
supply. Extension cords do not
In Massachusetts:
~
This dryer must be installed by a
licensed plumber or gas fitter.
guarantee the required safety of the
appliance (e.g. danger of overheating).
Before installation, disconnect the
~
This dryer must be vented outdoors
~
tumble dryer from the electrical supply
by shutting off the power main,
to reduce the risk of fire. Be sure to
observe local building codes.
unplugging the power cord or tripping
the circuit breaker. Do not restore
power until the installation is complete.
Use flexible or rigid metal pipe for
~
venting. Non-metallic flexible hose
should not be used, it is a potential fire
hazard.
GROUNDING INSTRUCTIONS
~
This appliance must be grounded. In
the event of malfunction or breakdown,
grounding will reduce the risk of
electric shock by providing a path of
least resistance for electric current. This
appliance is equipped with a cord
having an equipment grounding
conductor and a grounding plug. Only
place the plug in an appropriate outlet
that is properly installed and grounded
in accordance with all local codes and
ordinances.
5
IMPORTANT SAFETY INSTRUCTIONS
The dryer exhaust must not be
~
connected to a chimney, fireplace
ducting, a combustion appliance vent
flue, a wall, ceiling or concealed space
of a building.
Do not install the machine in rooms
~
where temperatures below freezing
may occur.
Proper installation is the
~
responsibility of the installer.
Product failure due to improper
~
installation is not covered under the
Warranty.
Gas dryers are not approved for
~
mobile home installation.
If there is any doubt concerning
~
installation, contact Miele’s Technical
Service Department.
U
V
1-800-999-1360
1-800-565-6435
6
Installation
Front view
a Exhaust connection
b Power cord with plug
c Control panel
Stand
A dryer stand, with drawer, can be
purchased as an optional accessory.
d Door
e Four height adjustable screw feet
7
Installation
Rear
a Handle for transportation (arrows)
b Power cord with plug
c Slot for module
,WARNING
Do not remove the restriction insert
in the vent opening. It may result in
poor drying results, damage to the
laundry and higher Carbon
monoxide emissions.
d Air intake
e Gas connection
f Vent connection with restriction insert
8
Installation site
,WARNING:
, The National Fuel Gas Code
restricts installations of gas
appliances in garages. They must
be 18 inches off the ground and
protected by a barrier from
vehicles.
Do not install the dryer:
- outdoors
- in an environment with dripping
water or weather
- near flammable materials
- in rooms which may contain gas
or other fuels
- in closets with solid doors
- with other fuel-burning
appliances in the same closet
- in a location where its door
could conflict with room doors.
- next to a refrigerator
- under a countertop
- on top of a washer.
9
Installation site
Confined space installation
Minimum installation clearance
^ When installed in any space with less
than 122 square feet, minimum
clearances around the dryer must be
adhered to for proper ventilation and
vents for make up air must be
installed.
^ Do not install any other fuel-burning
appliance in the same space as the
dryer.
Confined door openings
Any doors limiting circulation must be
louvered or otherwise ventilated.
A minimum of 200 square inches
(1,290 cm2) of opening is required. It
must be equally divided within 12"
(30.5 cm) from the top and bottom of
the door.
Sides: 0 " (0 cm)
Top: 12" (30.5 cm)
Rear: 0" (0 cm) (as close to wall as
gas connection and venting allows)
Front to door: 2" (5 cm)
Make sure the dryer door can open
completely once installed.
Exhaust duct clearance
to combustible material: 2" (5 cm)
10
Installation
Transporting the dryer to the
installation site
Level the dryer
The rear of the lid has a handle for
transportation.
^ Use the front dryer feet and the rear
of the lid to move the dryer to the
installation site.
The dryer must be level to ensure safe
and proper operation.
^ Unscrew the four feet as necessary
by turning the foot, 1, and the locking
ring, 2, to the left.
^ Once level, hold the foot, 1, still with
a wrench. At the same time, turn the
locking ring, 2, to the right using
another wrench.
,The dryer lid cannot be
removed.
11
Installation
,WARNING
Before installation, disconnect the
tumble dryer from the electrical
supply by shutting off the power
main or tripping the circuit breaker.
Be sure the dryer power cord is
unplugged from the wall.
Do not restore power until the
installation is complete.
Turn the dryer’s gas shutoff valve in
the supply line to the OFF position.
Disconnect and discard old flexible
gas connector and ducting material.
12
Electrical connection
The dryer is supplied with a 5’ 7"
(1.7 m) 3x14 AWG cord and a
NEMA 5-15 P plug, ready for
connection to a 120 V, 60 Hz, 15 A AC
power supply.
,GROUNDING INSTRUCTIONS
This appliance must be grounded.
In the event of malfunction or
breakdown, grounding will reduce
the risk of electric shock by
^ Plug the machine into a proper outlet.
providing a path of least resistance.
This appliance is equipped with a
cord having an equipment
If the plug does not fit, have a proper
outlet installed by a qualified
electrician.
grounding conductor and a
grounding plug. The dryer, when
installed, must be electrically
grounded in accordance with local
codes, or in the absence of local
codes, with the National Electrical
Codes ANSI/NFPA 70, or the
Canadian Electrical Code, CSA
C22.1.
WARNING – Improper connection of
the equipment grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician,
service representative or personnel
if you are in doubt as to whether the
appliance is properly grounded.
,WARNING – This dryer is
equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly
grounded three-prong receptacle.
Do not cut or remove the grounding
terminal from this plug.
Do not modify the plug! If it will not
fit the outlet, have a proper outlet
installed by a qualified electrician.
13
Gas connection
Gas type
,WARNING
The gas dryer is equipped for
connection to a NATURAL GAS
supply.
Installation and service must be
performed by a qualified installer,
service agency or gas supplier.
The maximum heat output is
19,500 BTU/H (5,7 kW).
In Massachusetts a licensed
plumber / gas fitter is required.
An installation kit for conversion from
NATURAL to LP gas is available as an
optional accessory.
This appliance must be installed
with its own shut off valve in the
same room. The valve must be
easily accessible to the consumer to
turn on or shut off the gas supply
after the appliance is installed.
A conversion to LP gas must only be
carried out by a Miele Authorized
Service Provider and in accordance
with all local codes and ordinances.
Minimum gas supply pressure
to obtain the required gas input is:
0.15 psi (4" WC) for natural gas
0.29 psi (8" WC) for LP gas.
During any pressure testing of the
gas system this appliance must be
disconnected from the gas supply
by closing its individual manual shut
off valve.
Maximum gas supply pressure
before the gas pressure regulator
0.37 psi (10" WC) for natural gas
0.46 psi (13" WC) for LP gas.
Any pipe connections must be made
using a thread sealant approved for
gas connections. Failure to correctly
install these items could lead to a
gas leak and subsequent explosion.
The gas installation must be made in
accordance with local codes or, in
the absence of local codes, with
-National Fuel Gas Code,
ANSI Z223.1/NFPA 54 for USA
or
-Natural Gas and Propane
Installation Code,
CSA B149.1 for Canada.
14
Gas connection
Gas supply
Installation material (hoses and
adapters) must be provided by the
installer.
Gas connection distances
aFlare union adapter
b1/8" NPT pressure tapping plug
cGas shut-off valve
For convenience (if allowed by code),
an AGA or CGA approved flexible
stainless steel gas hose (accordion
type) may be used between the gas
source and the dryer. This will allow the
appliance to be moved from the
installation site for cleaning or
This appliance must be installed with its
own shut off valve on the gas supply
line. The valve must be within 6 ft.
(1.8 m), and in the same room, of the
dryer.
servicing. Make sure that nothing rubs
on the gas hose.
An 1/8" NPT pressure tapping plug must
be installed immediately upstream of
the gas supply connection. This allows
the gas inlet pressure to be checked.
If there is any doubt concerning
installation, contact the Miele Technical
Service Department at the phone
number listed on the back of this
manual.
15
Gas connection
,
To secure all connections use
appropriate Teꢀon tape or a thread
compound.
Use a 10" slip joint wrench only.
^ Install a 3/8" ꢀare union adapter, a , to
the female elbow, b .
Hold the elbow with a wrench.
The maximum amount oꢁ orce used
should be 531 lbꢂ n. (60 Nm).
^ At the end of the dryer's gas
connection hand screw on the
3/8" NPT elbow.
Using a wrench tighten the elbow
with a half turn.
^ Secure the gas connection with
Teꢀon tape or thread compound.
^ Secure the ꢀexible metal gas line
connector to the adapter.
16
Gas connection
^ Using two wrenches tighten all
connections.
^ Using two wrenches tighten the
flexible gas line connection.
,DO NOT OVERTIGHTEN.
^ Connect the flare union adapter, a,
to the pressure tapping plug, b,
originally installed on the gas shut off
valve, c.
^ Open the gas shut-off valve.
^ After connecting the appliance
check all fittings for gas leaks e.g.
with soapy water or an equivalent.
,WARNING
NEVER USE AN OPEN FLAME TO
TEST FOR GAS LEAKS.
17
Ducting
Exhaust ducting and
connections
,WARNING
A gap of 3/8" (10 mm) must be
provided between the machine and
the floor. This gap is necessary for
proper air flow and must not be
blocked by a toe-kick or thick piled
carpets.
Danger of toxic fumes.
The exhaust gases from the dryer
must only be vented outside the
building.
DO NOT terminate the exhaust
ducts in a chimney, fireplace
ducting, a combustion appliance
vent flue, or enclosed,
Sufficient venting of the installation
site is essential for proper dryer
operation. Inadequate ventilation will
increase energy use and drying
times.
unventilated area such as attics,
garages, crawlspaces, walls,
ceilings or concealed space of a
building.
To reduce the risk of fire, only use
metal ductwork.
18
Ducting
How to calculate the effective
duct length
Tips about the ductwork
– Check with your local building code
to determine the maximum allowable
duct length.
The overall duct length will determine
the duct diameter.
– Rigid metal or flexible aluminum
ducting is preferred. Flexible foil
ducting may move and bounce due
to the high airflow of the dryer. This
could lead to a thumping or grinding
noise.
^ Measure the actual duct length
needed to go from the dryer’s
exhaust connection to the vent outlet:
1. Establish the number of elbows or
bends necessary, noting the type of
bend, angle and radius involved
(see Table).
– Non-metallic flexible hose should not
be used. It is a potential fire hazard.
2. Add the additional duct length (as
derived by using the values
specified in the table) to the actual
duct length to get the effective
length.
– For best drying results avoid extra
long ducting with too many bends,
angles or tight corners.
– The shorter the exhaust ductwork,
the more efficient the dryer will be.
Expelled air is slowed down in the
ducts due to friction against the inner
walls. The shorter and smoother the
inner walls are, the less friction will
be created.
Note:
Maximum effective duct lengths:
4" (100 mm) diameter
5" (125 mm) diameter
6" (150 mm) diameter
66 ft (20 m)
131 ft (40 m)
328 ft (100 m)
– An elbow or bend creates more
friction than a straight duct. An
additional duct length factor must be
added for each elbow or bend (see
Table). This factor expresses the
resistance of the bend in terms of a
straight length of duct.
Effective duct lengths over 66 ft (20 m)
require a larger duct diameter.
Longer ducts may lead to decreases in
dryer efficiency if the next larger duct
diameter is not followed.
The additional length factor is then
added to the existing duct to give the
effective duct length.
A larger duct diameter helps to
reduce friction. Therefore duct
diameter should be increased if
longer duct lengths are required.
19
Ducting
Additional duct lengths (4" (100 mm) rigid pipe only)
Type of bend
Radius
inches
Additional duct length
cm
ft
cm
Flexible metal duct
– 3’ 3" (1 m) straight
– 45° angle
5’ 11"
4’ 11"
8’ 2"
180
150
250
10"
10"
25
25
– 90° angle
Smooth metal duct
– 3’ 3" (1 m) straight
– 45° angle
3’ 3"
1’ 11"
2’ 7"
100
60
10"
10"
25
25
– 90° angle
80
Elbow 90° sharp
7’ 6"
2’ 4"
230
Concertina bend
– 90° angle
8"
20
70
Wall vent or window vent
– with louvers
12’ 5"
4’ 11"
19’ 8"
380
150
600
– with flap
– with weather hood
20
Ducting
Example
Rigid pipe
A
Duct length
ft
Duct length
m
12’ 5"
3.8 m
Wall duct with
louvered wall vent
B
C
D
2’ 4"
1’ 7"
0.7 m
0.5 m
0.7 m
5.7 m
90° bend
20" (0.5 m) rigid pipe
90° bend
2’ 4"
Total duct
length
18’ 8"
The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm)
with adapter is sufficient.
21
Ducting
Exhaust connection with a
flexible exhaust hose or rigid
pipe
,WARNING
Do not remove the restriction insert
in the vent opening. It may result in
poor drying results, damage to the
laundry and higher Carbon
monoxide emissions.
Using the connector supplied, an
exhaust hose (4" [100 mm]
diameter) can be installed.
Necessary materials:
The exhaust duct must not be
– a wall or window duct
(available from Miele)
connected or secured with screws
or other fastening devices which
extend into the interior of the duct.
– an exhaust hose made of approved
non-flammable material
^ Install the required connector*, 1,
with the exhaust hose or pipe, 2, to
the dryer.
* The white connector with clips is
used for connection to a hose; the
gray connector without clips is used
for connection to a pipe.
22
Ducting
Window connection (example)
Wall connection (example)
1 Window duct
1 Wall pipe (Installation sheet supplied
with the Miele wall pipe)
2 Connector for the rigid or flexible
exhaust hose
2 Connector
3 Rigid pipe
23
Ducting
Direct wall connection
Necessary materials:
– a wall pipe
Dryer side view
– flexible foam gasket
Dryer top view
1 Wall pipe
2 Flexible foam gasket
1 Wall pipe
2 Flexible foam gasket
^ Connect the flexible foam gasket, 2,
to the wall pipe connector, 1.
^ Push the dryer to the wall.
24
Caring for the environment
Disposal of the packing
materials
Disposal of an appliance
Old appliances may contain materials
that can be recycled. Please contact
your local recycling authority about the
possibility of recycling these materials.
The packing materials protect the
appliance during shipping. They have
been designed to be biodegradable
and recyclable.
Ensure that a discarded dryer presents
no danger to children. When being
stored for disposal remove the door to
the drying compartment.
To prevent suffocation, ensure that any
plastic wrappings, bags, etc. are
disposed of safely and kept out of the
reach of children.