INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Kickspace Heater
MODEL: 9114NT
PLAN THE INSTALLATION
IMPORTANT SAFETY INSTRUCTIONS
This heater is designed for installation in an enclosed space such
as under a counter or kickspace to provide warm, gentle heat at the
floor level. Reread Safety Notes 3 through 8 for guidelines in plan-
ning the installation.
The Model 9114NT is factory wired for 240/208 V.A.C. operation. It
offers a choice of heat outputs and can be internally connected for
multiple wattages at different voltages shown in the table below.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. All electrical work must be done in accordance with local and/
or National Electrical Code as applicable. For safety, this prod-
uct must be grounded. If you are unfamiliar with methods of
installing electrical wiring, secure the services of a qualified
electrician.
2. Turn off power at service entrance before installing wiring, ser-
vicing, or cleaning this product.
VOLTS
240
208
120*
120*
WATTS
1500
1125
1500
750
AMPS
6.3
5.4
12.5
6.3
BTU/HR
5120
3840
5120
2560
3. Do not install heater upside down or sideways. Heater must
be located in the horizontal position.
4. Do not recess louvered face of the heater more than three
inches from the vertical face of any overhang (cabinet).
All ratings are 1-Phase, 60 Hertz.
*See “FIELD CONVERSION TO 120 V.A.C.” section.
5. Do not locate heater behind doors, furniture, etc., where the
air flow to the unit will be restricted.
6. To avoid electrical shock; do not install heater within arm’s
length of tub or shower enclosure.
FIELD CONVERSION TO 120 V.A.C.
Refer to FIGURE 1
If a 120 V.A.C. circuit is to be used, make wiring changes as fol-
lows:
1. Disconnect white wire from heater element terminal “2” and
connect it to terminal “4.” The heater will now operate at 120
V.A.C., 750W, 6.3A.
7. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc., off power
unit.
8. Provide this heater with a separate electrical circuit following
directions under “Wire the Heater” section.
9. This product is equipped with a thermostat which may start it
automatically. Turn off power at service entrance before clean-
ing or servicing.
10. This heater includes a visual alarm to warn that parts are get-
ting excessively hot. If the alarm lights are activated, immedi-
ately turn the heater off and inspect for any objects on or adja-
cent to the heater that may cause high temperatures.
2. For 120 V.A.C, 1500W, 12.5A operation, add the short red
jumper wire (provided) between terminals “1” and “2”.
3. Remove alarm light wire leads from terminals “1” and “3” of the
high temperature limit. Remove white wire lead from limit ter-
minal “1” and reconnect at limit terminal “3”. Secure wire leads
with wire tie so there is no interference with unit operation.
NOTE: Terminal numbers are marked on the side of the blower
housing, above the heater elements.
11. Please read specification label on product for further informa-
tion and requirements.
FIGURE 1
WIRE THE UNIT
WARNING: Disconnect power at service entrance before wir-
ing this product.
Refer to FIGURE 5
1. Run electrical power cable to installation location. Provide two
feet of slack to allow heater to be pulled out far enough to re-
move top cover for cleaning or servicing.
NOTE: It is recommended that flexible conduit be used for field
wiring to the unit to protect the wires from sharp objects or hazard-
ous environments.
NOTE: Be sure supply voltage meets the equipment requirement.
Refer to the rating plate, unit wiring diagram and specification table.
FIGURE 5
Refer to FIGURE 6
2. Remove top cover for access to wiring box at rear of heater.
Refer to FIGURE 7
3. Remove one of the two knockouts and connect power cable to
heater using appropriate connector. Allow at least six inches of
wiring inside of wiring box.
4. Connect black to black, white to white and green (or bare wire)
to ground screw, as shown. Tuck wires down inside the wiring
box.
5. Replace top cover.
WARNING: Do not operate heater without top cover in place.
6. Slide heater into place and secure to mounting surface.
FIGURE 6
CHECK OPERATION
1. Turn thermostat counterclockwise to its lowest setting.
2. Turn on power to circuit at service entrance.
3. Turn thermostat clockwise. The heating element and fan should
come on. Set thermostat to desired temperature level. During
proper operation, the heater will cycle on and off periodically.
If heater does not come on:
1. Return the thermostat to lowest setting.
2. Shut off power at service entrance.
3. Remove the top cover, Check for proper line voltage and rein-
spect wiring connections. Reread installation procedure mak-
ing sure all steps were followed.
4. Also check the thermal fuse. It may be open and need to be
replaced. Consult the service parts list for the part number of a
replacement fuse. Follow the procedure described in the last
paragraph of the warranty when ordering replacement parts.
FIGURE 7
MAINTENANCE
NOTE: Always disconnect power at service entrance before clean-
ing or servicing heater.
The only maintenance required for this heater is to periodically
vacuum the front grille and housing. Simply remove the two side
angle support screws, slide heater out, and remove top cover for
access to the blower housing.
PARTS LIST
PART
REF.
NUMBER PART DESCRIPTION
1
2
3
4
5
6
7
8
99522899 Cover (White)
99522400
99521763
99521765
99020130
99521760
99521761
Cycling Thermal Overload Limit Switch
Thermal Fuse
Motor
Blower Wheel
Motor Plate
Element Retainer
99271288 Heater Element (2 Required)
9
99521767
---
99521770
99521768
99521769
*
Thermostat (Optional)
Housing (White)
10
11
12
13
14
Cupped Washer
Strain Relief Bushing
Knob (Optional)
Screw, 6-20 x 1/4 Slotted Hex Head
(2 Required)
15
*
Screw, 6-20 x 3/8 Slotted Head Head AB
Pt.
16
17
*
*
Nut, 6-32 Hex Keps (2 Required)
Screw, 10-16 x 3/8 Slotted Head Head
AB Pt.
18
19
*
*
Nut, 10-32 Hex Keps (2 Required)
Screw, 10-32 x 1/2 Slotted Head Head
Type F
8
20
21
*
*
Screw, 6-32 x 3/4 Phillips Pan Head
(2 Required) (Optional)
Screw, 8-18 x 1/4 Slotted Pan Head
(4 Required)
22
23
99522062
99522782
Plastic Hole Plug (2 Required)
Alarm Light
* Standard Hardware. May be purchased locally.
NUTONE ONE YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of our products that such products will be free from defects in materials or
workmanship for a period of one year from date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR PURPOSE.
During this one-year period, NuTone will, at our option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a)
normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by us), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAM-
AGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty super-
sedes all prior warranties.
To qualify for warranty service, you must (a) notify us at the address or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must
present evidence of the original purchase date.
NuTone, Inc.
4820 Red Bank Road
Cincinnati, OH 45227
(1-800-543-8687)
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., 5/03, Part No. 99044026B
|