Remote Thermometer Sensor
Model: THN122N
INTRODUCTION
Thank you for selecting the Oregon Scientific™ Remote
Thermometer Sensor (THN122N). This product is
compatible with various wireless weather station
products, such as the RAR621 and BAR623P.
USER MANUAL
CONTENTS
Introduction .............................................................. 1
Product Overview .................................................... 2
Remote Sensor (THN122N)................................... 2
Getting Started ......................................................... 3
Batteries ................................................................. 3
Remote Sensor (THN122N) ..................................... 3
Setup Sensor ......................................................... 3
Safety and Care ........................................................ 4
Warnings ................................................................... 4
Troubleshooting ....................................................... 5
Specifications........................................................... 5
Remote Sensor Dimensions .................................. 5
Remote Sensor (THN122N)................................... 5
Power ..................................................................... 5
About Oregon Scientific .......................................... 6
EC-Declaration of Conformity ................................. 6
Keep this manual handy as you use your new product.
It contains practical step-by-step instructions, as well as
technical specifications and warnings you should know.
1
THN122N_EN_R3
1
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
1/8
4. Place the sensor near the main unit. Press RESET on
the sensor. Then, press the appropriate main unit button
(as specified in the main unit manual) to initiate signal
sending between the sensor and the main unit. The
reception icon on the main unit will blink for approximately
3 minutes while it is searching for the sensor.
5. Close the remote sensor battery compartment.
6. Secure the sensor in the desired location using the
wall mount or table stand.
GETTING STARTED
BATTERIES
Remote unit
2 x UM-4 (AAA) 1.5V batteries
Insert batteries before first use, matching the polarity
(+ and -) as shown in the battery compartment. For best
results, install batteries in the remote sensor before the
main unit. Press RESET after each battery change.
Installing the batteries:
NOTE Do not use rechargeable batteries.
NOTE It is recommended that you use alkaline batteries
with this product for longer performance.
REMOTE SENSOR (THN122N)
SETUP SENSOR
1. Open the remote sensor battery compartment with
a small Phillips screwdriver.
2. Insert the batteries, matching the polarity (+ and -)
as shown in the battery compartment.
3. Set the channel switch to any channel. The switch is
located in the battery compartment.
3
THN122N_EN_R3
3
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
3/8
Using the stand or wall mount:
•
Position the sensor close to the main unit during
cold winter months as below-freezing
temperatures may affect battery performance and
signal transmission.
You may need to experiment with various locations to
get the best results.
DATA TRANSMISSION
SAFETY AND CARE
Clean the product with a slightly damp cloth and alcohol-
free, mild detergent. Avoid dropping the product or
placing it in a high-traffic location.
For best results:
•
•
•
•
Insert the batteries and select the channel before
you mount the sensor.
Place the sensor out of direct sunlight and
moisture.
Do not place the sensor more than 30 metres
(98 feet) from the main (indoor) unit.
Position the sensor so that it faces the main
(indoor) unit, minimizing obstructions such as
doors, walls, and furniture.
WARNINGS
This product is designed to give you years of service if
handled properly. Oregon Scientific will not be
responsible for any deviations in the usage of the device
from those specified in the user instructions or any
unapproved alterations or repairs of the product. Observe
the following guidelines:
•
Place the sensor in a location with a clear view
to the sky, away from metallic or electronic
objects.
•
•
Never immerse the product in water. This can
cause electrical shock and damage the product.
Do not subject the product to extreme force,
shock, or fluctuations in temperature or humidity.
4
THN122N_EN_R3
4
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
4/8
•
•
Do not tamper with the internal components.
Do not mix new and old batteries or batteries of
different types.
SPECIFICATIONS
REMOTE SENSOR DIMENSIONS
•
•
•
Do not use rechargeable batteries with this
product.
Remove the batteries if storing this product for a
long period of time.
L x W x H
92 x 60 x 20 mm
(3.6 x 2.4 x 0.79 inches)
Weight
63 grams (2.22 ounces)
without battery
Do not scratch the LCD display.
NOTE The technical specification of this product and
contents of this user guide are subject to change without
notice. Images not drawn to scale.
REMOTE SENSOR (THN122N)
RF frequency
433 MHz
Range
30 metres (98 feet)
with no obstructions
TROUBLESHOOTING
PROBLEM
Remote sensor
SYMPTOM
Cannot locate
remote sensor
REMEDY
Check batteries
Check location
Transmission
Channel No.
Every 40 seconds
1-3
Data does not
match main unit
Initiate a manual
sensor search
POWER
Sensor batteries
2 x UM-4 (AAA) 1.5V
NOTE It is recommended that you use alkaline batteries
with this product for longer performance.
5
THN122N_EN_R3
5
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
5/8
EC-DECLARATION OF CONFORMITY
ABOUT OREGON SCIENTIFIC
Hereby, Oregon Scientific, declares that this Remote
Thermometer Sensor is in compliance with the essential
requirements and other relevant provisions of Directive
1999/5/EC.
more about Oregon Scientific products such as digital
cameras; MP3 players; children's electronic learning
products and games; projection clocks; health and fitness
gear; weather stations; and digital and conference
phones. The website also includes contact information
for our customer care department in case you need to
reach us, as well as frequently asked questions and
customer downloads.
A copy of the signed and dated Declaration of Conformity
is available on request via our Oregon Scientific
Customer Service.
We hope you will find all the information you need on
our website, however if you'd like to contact the Oregon
Scientific Customer Care department directly, please
visit:
www2.oregonscientific.com/service/support
OR
Call 949-608-2848 in the US.
For international enquiries, please visit:
www2.oregonscientific.com/about/international/default.asp
COUNTRIES RTTE APPROVAL COMPLIED
EC-DECLARATION OF CONFORMITY
CH
All EC counties, Switzerland
and Norway
N
6
THN122N_EN_R3
6
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
6/8
Remote Thermometer Sensor
Model: THN122N
USER MANUAL
THN122N_EN_R3
7
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
7/8
©2005 Oregon Scientific. All rights reserved.
086-003693-016
THN122N_EN_R3
8
12/4/04, 3:14 PM
P/N: 086-003693-016 EN REV1
8/8
|