LONG-RANGE WIRELESS WEATHER STATION
WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK
MODEL : BAR898HGA
USER'S MANUAL
As part of the weather forecasting function, the unit has a built-
in barometer that displays atmospheric pressure. Using kinetic-
INTRODUCTION
movement graphic illustrations the unit displays atmospheric
pressure trends and displays forecasts as sunny, partly cloudy,
cloudy, rainy and snowy.
Congratulations on your purchase of the BAR898HGA Long-
Range Wireless Weather Station with In-Out Thermo-Hygrometer
and RF Clock. This unit is an all-in-one weather forecasting
device which has multiple weather-related functions. Also, with
an internal antenna the reception range of this unit can be up to
100 meters.
This unit also has a Radio Frequency (RF) controlled clock. It can
automatically synchronize its current time and date when it is
brought within range of the radio signal generated from the U.S.
Atomic Clock.
The BAR898HGA, a weather forecasting device, has several
weather related functions. The main feature is that it takes and
records temperatures and humidities in more than one location.
Other features of BAR898HGA include LCD and key-panel
backlight, rotatable display unit for multi-angle viewing and a
Daily crescendo alarm with an eight-minute snooze function.
Using
a
wireless remote thermo-hygro sensor, it can
simultaneously monitor temperatures and humidities in three
remote locations. The unit will show temperature and humidity
trends as well as record maximum and minimum temperature
and humidity readings. BAR898HGA is able to receive and
display readings from up to 3 remote sensors.
No wire installation is required between the main and remote
units as this unit operates at 433 MHz.
However, please note that the Atomic Clock cannot be used
outside the U.S.
1
B3. [ MEMORY ] BUTTON
- Displays minimum and maximum temperature and
humidity readings, and erases memory data
B4. [ CHANNEL ] BUTTON
- Displays the temperature and humidity readings of the
indoor or remote sensor
B5. [ SNOOZE / LIGHT ] BUTTON
- Activates the snooze function or turn on the backlight
B6. DETACHABLE TABLE - STAND
( [ SNOOZE / LIGHT ] STAND - BUTTON)
- Acts as the [ SNOOZE / LIGHT ] BUTTON when attached to
the display unit
C. CONTROL BUTTONS
-
SIDE PANEL
C1 & C2. UP [ ] & DOWN [ ] BUTTONS
- Increases or decreases the value of a setting
D. CONTROL BUTTONS
-
BACK PANEL
D1. BATTERY COMPARTMENT
- Accommodates four (4) pieces of UM-3 or "AA" size
batteries
D2. [ HISTORY ] BUTTON
- Displays the barometric reading for the last 24 hours, or
enter the altitude compensation setting
3
D3. [ mb / hPa - inHg ] SLIDE SWITCH
- Selects between "mb / hPa" or "inHg" pressure unit
display
D4. [ °C / °F ] SLIDE SWITCH
- Selects between Centigrade (°C ) or Fahrenheit (°F)
temperature unit display
D5. [ZONE] BUTTON
Press to select among the 4 U.S. time-zones: Pacific(P),
Mountain(M), Central (C) or Eastern (E)
D6 & D7. ALT ( ) or ALT ( ) BUTTON
Increases or decreases the value in compensational
altitude setting respectively
D8. [ RESET ] BUTTON
- Resets the unit by returning all setting to their default
values
FEATURES : REMOTE
THERMO-HYGRO SENSOR
d. Channel slide switch
a. Two-line LCD
Designates the remote unit Channel 1, Channel 2 or
Channel 3
Displays the current temperature and humidity monitored
by the remote unit
e. RESET
b. LED indicator
Returns all settings to default values
Flashes when the remote unit transmits a reading
f. Battery compartment
c. °C/°F slide switch
Accommodates two (2) pieces of UM-3 or AA-size batteries
Selects between Centigrade (°C) and Fahrenheit (°F)
4
g. Battery door
NOTES ON OPERATION
h. Wall-mount holder
For best operation:
Supports the remote unit in wall-mounting
1. Insert batteries for the main unit first. Then proceed with
inserting the batteries for the remote unit.
i. Removable table stand
For standing the remote unit on a flat surface
2. Position the remote unit and the main unit within effective
transmission range. In usual circumstances, the effective range
is up to 100 meters or 300 feet.
BEFORE YOU BEGIN -
INSTALLING THE TABLE STAND
3. Though the remote unit is weather resistant, it should be
placed away form direct sunlight, rain or snow.
Before operation, plug
the detachable table stand
into the display unit as
shown.
BATTERY INSTALLATION: MAIN UNIT
1. Gently open the battery compartment door as shown.
You can rotate the display unit freely by moving the unit around.
2. Insert four (4) pieces of UM-3 or "AA" size batteries in
accordance with the polarities shown.
3. Close the battery compartment door.
5
BATTERY AND CHANNEL INSTALLATION:
REMOTE UNIT
LCD AND KEY-PANEL BACKLIGHT
For easy viewing in the dark this unit is featured with backlight
function on the LCD display as well as on the front key-panel.
The remote thermo-hygro sensor unit uses two (2) UM-3 or
“AA” size batteries.
The unit is designed such that you can conveniently use the
backlight feature irrespective of whether the unit is wall-mounted
or free standing on the table.
Follow these steps to install / replace batteries:
Wall-Mount
Table-Stand
1. Remove the screws on the battery compartment.
2. Select the channel number on the CHANNEL slide switch.
3. Select the temperature display unit on the °C/°F slide switch.
Press the corresponding [ SNOOZE / LIGHT ] button or the
button on the stand. The backlight will be activated for 5 seconds.
4. Insert the batteries strictly according to the polarities shown
therein.
ABOUT RADIO RECEPTION
5. Replace the battery compartment door and secure its screws.
Replace the batteries when the low-battery indicator of the par-
ticular channel lights up on the main unit.
The BAR898HGA is designed to automatically synchronize its
calendar clock once it is brought within range of the US Atomic
Clock radio signal.
Note that once a channel is assigned to a remote unit, you can
When the BAR898HGA is within range, its radio-control mecha-
nism will override all manual settings unless the auto-reception
function is manually disabled.
only change it by removing the batteries or resetting the unit.
6
When the unit is receiving radio signal, the RADIO RECEPTION
signal will start to blink. A complete reception generally takes
about 2 to 10 minutes, depending on the strength of the radio
signal.
Note: When changes are made to this setting, the seconds will
start from zero.
Press [MODE] again, the calendar settings are displayed and the
year is flashing. Use the UP [ ] or DOWN [ ] button to change
the year.
When the reception is complete, the RADIO RECEPTION signal
will stop blinking. The strength of the reception for the last full
hour will be indicated.
Press [MODE] button and the month will flash. Enter the
appropriate month using the UP [ ] or DOWN [ ] button.
For better reception, place the clock away from metal objects
and electrical appliances to minimize interference.
Press [MODE] button and the day settings will flash. Enter the
appropriate day using the UP [ ] or DOWN [ ] button.
Should you wish to deactivate the RF controlled function, press
and hold the [ZONE] button.
Press [MODE] again and the language setting will flash. Use the
UP [ ] or DOWN [ ] button to select E for English, F for
French or S for Spanish.
To reactivate the RF control function, press and hold the UP
[
] button.
Press [MODE] to complete and exit the setting.
Chart Indicating Radio Signal Strength
The weekday can be expressed as an abbreviation in three
different languages. The languages and their selected
abbreviations for each day of the week are shown in the language
chart below.
Good
No signal
Receiving
Day-of-the-week
Language
Monday Tuesday Wed. Thursday Friday Saturday Sunday
English
French
HOW TO MANUALLY SET THE CLOCK
Press [MODE] and hold for three seconds.
The hour will flash. Use the UP [ ] or DOWN [ ] button to
enter the hours. Holding down either the up or down button will
increase or decrease the value rapidly.
Spanis
To toggle among the 4 U.S. time-zones, press the [ZONE] button.
Press [MODE] again, the minute will flash. Again, use the UP
[
] or DOWN [ ] button to change the minutes.
7
To stop the alarm, press the [ALARM] button. However, if
[ SNOOZE / LIGHT ] is pressed, the SNOOZE function will be
triggered. The alarm will stop and the ALARM ON icon blinks
for eight minutes. After that the alarm will go off again.
HOW TO SET AND ACTIVATE THE ALARM
To set the Alarm
Press [ALARM] button to display the daily alarm time (the icon
To deactivate the SNOOZE function, press the [ALARM] button.
"
" will be displayed)
Press [ALARM] and hold for three seconds, the value for the
hour will flash.
CHECKING INDOOR AND REMOTE
TEMPERATURES & HUMIDITIES
Press UP [ ] or DOWN [ ] buttons to make changes to the
alarm hour setting.
To display the indoor and outdoor temperature and humidity
readings, press the [CHANNEL] button to toggle among the
indoor, Channel 1, 2 and 3 displays.
Press [ALARM] and the minute digits will flash. Enter the value
for the minute by using UP [ ] or DOWN [ ] buttons.
Press [ALARM] to exit.
The temperature can be shown in Centigrade (°C) or Fahrenheit
(°F). Select the appropriate reading by using the °C/°F slide
switch (located in the battery compartment). Slide the switch to
°C for Centigrade or °F for Fahrenheit.
The alarm is automatically activated. The ALARM ON icon [
is visible and the alarm will be activated at the specified time.
]
To deactivate the daily alarm function, press the [ALARM] button
when the alarm time is displayed. The ALARM ON icon will
disappear.
This unit has an auto-scan function that can sequentially display
the indoor and remote readings.
To activate this function, press and hold the [CHANNEL] button
for 3 seconds. To deactivate press the [CHANNEL] button again.
To activate, press the [ALARM] button again.
If the reading goes above or below the specified amounts, the
display will show a flashing “HHH” or “LLL”.
ALARM AND SNOOZE FUNCTION
When the daily alarm goes off, the backlight will be on for five
seconds and the ALARM ON icon [ ] will flash.
NOTE ON REMOTE READINGS
The alarm function has a built in crescendo type alarm system.
Initially, the active alarm will have a gentle sound. The intensity
will increase in three stages. Without interruption, the unit will
alarm for two minutes.
Once batteries are in place in the remote unit, it will start trans-
mitting samplings at 40 second intervals.
If no signals are received when the remote sensor display is
selected, “
” will be displayed. To initiate the main unit
8
search for remote sensor signals, press [MEMORY] and
[CHANNEL] simultaneously.
TEMPERATURE & HUMIDITY TREND
The temperature and humidity trend indicator shows the trend
of temperatures and humidities collected at that particular sensor.
Three trends: rising, steady, and falling will be shown.
If that fails, check if the remote sensor is still in place. Make sure
the transmission is within range and the path is clear of obstacles
and interference.
Repeat this procedure whenever you find discrepancies between
the display on the main unit and the display on the remote
sensor.
Arrow
indicator
Temperature
Rising
Steady
Falling
NOTE ON °C AND °F
Trend
The outdoor temperature display on the main unit is dominated
by the selection on the °C/°F slide switch of the main unit.
Whatever the display unit of the remote sensor is, it will only
apply to the remote sensor itself and the temperature will be
automatically converted to the chosen one of the main unit.
Arrow
indicator
Humidity
Trend
Rising
Steady
Falling
MAXIMUM AND MINIMUM
TEMPERATURES & HUMIDITIES
ATMOSPHERIC PRESSURE
The maximum and minimum recorded temperatures and
humidities will be automatically stored in memory. To display
them, press [MEMORY]. Press [MEMORY] again to alternate
between the maximum, minimum and current readings. The
respective MAX or MIN indicator will be displayed.
The atmospheric pressure arrow indicator will indicate if the
atmospheric pressure is increasing, remaining stable, or
decreasing.
Arrow
indicator
To clear the memory, press [MEMORY] and hold for three
seconds. The maximum and minimum recorded readings will be
erased. Subsequently, if you press [MEMORY] after the memory
has been erased, the maximum and minimum readings will have
the same values as the current ones.
Pressure
Trend
Rising
Steady
Falling
9
Indicator
displays
on the unit
Shows that the
Current
Environment
WEATHER FORECAST
Temperature
Range
Humidity
Range
The unit is capable of detecting atmospheric pressure changes.
Based on collected data, it can predict the weather for the
forthcoming 12 to 24 hours. The effective range covers an area
of 30 to 50 km or 18 to 35 milees.
Ideal range for
both relative
humidity and
temperature
20°C to 25°C 40%RH-
(68°F to 77°F) 70%RH
Contains excess
moisture
-5°C -+ 50°C
(23°F - 122°F)
OVER-
70%RH
Contains
inadequate
moisture
Below
40%RH
Sunny Partly cloudy
Cloudy
Rainy
Snow
-5°C -+ 50°C
(23°F - 122°F)
Less than
20°C (68°F) or
More than
NOTE:
40%RH
to
70%RH
No
Indicator
No comment
1. The accuracy of a general pressure-based weather forecast is
about 70% to 75%.
25°C (77°F)
2. The weather forecasts from this unit are predictions that
cover the next 12 to 24 hours. It may not necessarily reflect
the current situation.
HOW TO CHECK
THE BAROMETRIC PRESSURE
3. The "Sunny" icon, as applies to night time, implies clear
weather.
The current and historical barometric pressure is shown on the
atmospheric pressure window.
COMFORT LEVEL INDICATORS
For users staying at a higher altitude such as in the mountain
area, sea-level barometric pressure applies. In this case, press
and hold [HISTORY] button to enter the altitude compensation
The comfort level indicators COM, WET or DRY will tell you if
the current environment is comfortable, too wet or too dry.
The comfort indicator will appear on the display when the
following conditions are satisfied:
setting mode. Use the ALT (
from –328 to 8200 feet (whichever appropriate). Press
) or ALT (
) button to select
[HISTORY] button to confirm and exit.
10
The BAR898HGA requires entry of elevation in meters not feet.
To convert feet to meters multiply feet by .30.
Wall-Mount:
Table-Stand:
To determine your location elevation, please either contact
your local library, TV/radio weather forecaster, or via Internet at
The atmospheric pressure can be displayed in mb/hPa or inHg.
The pressure unit is selected on the atmospheric pressure slide
switch inside the battery compartment.
If you want to check the pressure history for a particular hour
during the past 24 hours, press the [HISTORY] button. Each
press on the button will go back by an hour. Holding down the
button will increase the value rapidly.
HOW TO WALL MOUNT OR USE THE
TABLE STAND (MAIN UNIT)
LOW BATTERY INDICATION
The unit can be wall-mounted using its recessed screw holes or
placed on a flat surface using the detachable table stand.
When it is time to replace batteries, the respective low battery
indicator [
] will show up when the corresponding channel is
selected. The battery level of the main unit is shown on the
Weather Forecast Window when it is running low.
Wall-Mount:
Table-Stand:
Gently plug in the table stand
as shown:
HOW TO WALL MOUNT OR USE THE
TABLE STAND (REMOTE UNIT)
As for the remote unit, it comes with a wall-mount holder and a
removable stand. Use either to hold the unit in place.
11
5. Only use new batteries as specified in this instruction manual.
Do not mix new and old batteries as the old batteries may
leak.
HOW TO RESET THE UNIT
The [ RESET ] button allows you to return all settings to factory
values. Accessing the slot is required only when the unit is
not operating in a favorable way such as in the rare case of a
malfunction.
6. Read this instruction manual thoroughly before operating
the unit.
The [ RESET ] slot is located inside the battery compartment
door. To use the button:
SPECIFICATIONS
Main unit
1. Open the battery compartment door.
2. Place a blunt stylus into the hole and press.
3. Close the battery compartment door.
Indoor Temperature measurement
Proposed operating range : -5.0°C to +50.0°C
(23.0°F to 122.0°F)
Temperature resolution
: 0.1°C (0.2°F)
MAINTENANCE
When handled properly, this unit is engineered to give you
years of satisfactory service. Here are a few product care
instructions:
Relative Humidity measurement
Measuring Range
Humidity Resolution
Remote unit
: 25% RH to 95% RH
at 25°C (77°F)
1. Do not immerse the unit in water. If the unit comes in contact
with water, dry it immediately with a soft lint-free cloth.
: 1% RH
2. Do not clean the unit with alcohol containing detergent,
abrasive or corrosive materials. Abrasive cleaning agents
may scratch the plastic parts and corrode the electronic circuit.
RF Transmission Frequency : 433 MHz
No. of Remote unit
RF Transmission Range
Data sensing cycle
: Up to 3 units
3. Do not subject the unit to excessive: force, shock, dust,
temperature, or humidity. Such treatment may result in
malfunction, a shorter electronic life span, damaged batteries,
or distorted parts.
: Up to 100 meters or 300 feet
: around 40 seconds
4. Do not tamper with the unit's internal components. Doing so
will terminate the unit's warranty and may cause damage.
The unit contains no user-serviceable parts.
12
Temperature measurement
Dimensions
Display range
: -20.0°C to +60.0°C
(-4.0°F to 140.0°F)
Main unit
: 195 (L) x 105 (W) x 77 (T) mm
or 7.68 x 4.13 x 3.03 inches
: 105 (L) x 70 (W) x 21 (T) mm
or 4.13 x 2.76 x .83 inches
Remote sensing unit
Proposed operating range : -5.0°C to +60.0°C
(23.0°F to 140.0°F)
Temperature resolution
: 0.1°C (0.2°F)
Relative Humidity measurement
CAUTION
Measuring Range
: 25 to 90%RH at 25°C (77°F)
: 1% RH
—
—
—
—
The content of this manual is subject to change without
further notice.
Humidity Resolution
Barometric Pressure measurement
The technical specifications of this product are subject
to change without notice.
Pressure measuring range : 795 to 1050mb / hPa
(23.48 to 31.01 inHg)
Due to printing limitation, the displays shown in this
manual may differ from the actual display.
Power
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Main unit
: uses four (4) UM-3 or "AA"
1.5V batteries
Remote sensing unit
: uses two (2) UM-3 or "AA"
1.5V batteries
Weight
NOTE ON COMPLIANCE
Main unit
: 300gm or 10.58 ounces
(without battery)
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause
undesired operations.
Remote sensing unit
: 80gm or 2.82 ounces
(without battery)
13
Warning: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Company Name : Oregon Scientific, Inc.
Address : 19861 SW 95th Place, Tualatin, Oregon 97062, USA
Telephone Number : 503-639-8883
FCC :
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable
Name and model number of the product : Baro w/Remote Thermo
Hygro BAR898HGA
protection against harmful interference in
a
residential
installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications.
CUSTOMER ASSISTANCE
Should you require assistance regarding this product and its
operation, please contact our customer care department at
800-853-8883 or via email at [email protected].
However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
WARRANTY
This product is warranted to be free of manufacturing defects for
a period of 90 days from date of retail purchase. Defective product
should be directed to the place of retail purchase for exchange.
! Reorient or relocate the receiving unit.
! Increase the separation between the equipment.
Should this not be possible, contact our customer care department
for assistance and a return material authorization. No returns
may be made without a return authorization. Warranty exchanges
require proof of date of purchase (purchase receipt showing date,
place and product purchased).
! Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
! Consult the dealer of an experienced radio/TV technician for
help.
This warranty does not cover product subjected to abuse, misuse,
accidental damage or tampering.
14
|