SERIES
EQ-500
Multi-voltage Amplifier Built-in
ADJUSTABLE RANGE REFLECTIVE
PHOTOELECTRIC SENSOR
Long sensing range 2.5 m
Multi-voltage
Not affected by background objects
EQ50Ⅺ
Because it can function with 24 to 240 V AC and 12 to 240 V
DC, almost any power supply anywhere in the world will do.
Because the sensor doesn’t detect objects outside the preset
sensing field by using the 2-segment photodiode adjustable
range system, it will not malfunction even if someone walks
behind the sensing object or machines or conveyors are in
the background.
EQ51Ⅺ
Impervious to variations color or angle
Introducing the new DC-voltage type
equipped with BGS / FGS function
Due to its advanced optical system, the sensor is not affected
by variations in the object’s angle or gloss compared to
conventional sensors.
Moreover, as the difference in sensing range between black
and white varies by only approx. 5 % (Note), sensing can be
performed at a somewhat constant distance even if the
sensing object is black or white.
We’ve added a DC-voltage type with NPN and PNP
transistor outputs all in one sensor. Its BGS / FGS function
controls any background effects for more stable sensing.
Refer to p.196 for the BGS / FGS functions.
Note: Example of the difference in sensing range between
black non-glossy paper (Lightness: 5) and white non-
glossy paper when the setting distance is set at 2 m
6.562 ft.
194
08/2005
EQ-500
BGS / FGS FUNCTIONS MAKE EVEN THE MOST CHALLENGING SETTINGS POSSIBLE!
The BGS function is best suited for the following case
Background not present
BGS (Background suppression) function
When object and background are
separated
The sensor judges that an object is present when light is received at position A of
the light-receiving element (2-segment element). This is useful if the object and
background are far apart. Not affected if the background color changes or
someone passes behind the conveyor.
OFF
Light received at element
B or light not received
ON
Light received at
element A
Element A
Element B
Moving object
in the back
Object
Setting distance
The FGS function is best suited for the following case
Background present
FGS (Foreground suppression) function
When object and background are close
together
When the object is glossy or uneven
The sensor judges that no object is present when light is received at position B of
the light receiving element (2-segment element)(The conveyor is detected). This
function is useful if the object and the background are close together or if the
object is glossy or uneven. However, sensing is impossible if there is no
background (conveyor, etc.)..
OFF in this condition only
Object absent
ON in all other conditions
For glossy
object
ON
Object present
ON
OFF
Element A
Emitting
element
Element B
Lens
Setting
distance
Conveyor
Conveyor
Conveyor
Light received at element B
A conveyor or other
Light received
at element A
Light is not received at
element B, so an object
is judged to be present
background must be present.
196
08/2005
EQ-500
OPTIONS
Type
Appearance
Sensing range
Model No.
Supply voltage
Output
Timer function
EQ-501
EQ-501T
EQ-502
EQ-502T
EQ-511
0.1 to 2.5 m
0.328 to 8.202 ft
24 to 240 V AC
ע 10 % ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
W
or
Relay contact 1a
12 to 240 V DC
ע 10 % M
0.1 to 1.0 m
0.328 to 3.281 ft
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
W
0.1 to 2.5 m
0.328 to 8.202 ft
NPN open-collector
transistor
PNP open-collector
transistor
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
EQ-511T
EQ-512
EQ-512T
12 to 24 V DC
ע 10 % Equipped with
2 outputs
(
)
0.1 to 1.0 m
0.328 to 3.281 ft
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
OPTION
Sensor mounting bracket
Designation
Sensor mounting bracket
Model No.
Description
Foot / back angled mounting bracket
• MS-EQ5-01
Two M5 (length 30 mm 1.181 in)
screws with washers and two
nuts are attached.
MS-EQ5-01
197
08/2005
EQ-500
SPECIFICATIONS
Multi-voltage
With timer
EQ-501T
DC-voltage
With timer
EQ-511T
Type
With timer
With timer
Item
Model No.
EQ-501
EQ-502
EQ-502T
EQ-511
EQ-512
EQ-512T
Adjustable range (Note 1) (Note 2) 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft
Sensing range (at maximum setting distance) (Note 2)
0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft 0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft
10 % or less of operation distance
Hysteresis
24 to 240 V AC
ע 10 % or 12 to 240 V DC ע 10 % 12 to 24 V DC
ע 10 % Ripple P-P 10 % or less Ripple P-P 10 % or less
Supply voltage
AC: 4 VA or less AC: 5 VA or less AC: 4 VA or less AC: 5 VA or less
45 mA or less
Power / Current consumption
DC: 3 W or less DC: 4 W or less DC: 3 W or less DC: 4 W or less
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 100 mA sink current)
Relay contact 1a
• Switching capacity: 250 V AC 3 A (resistive load)
30 V DC 3 A (resistive load)
0.4 V or less (at 16 mA sink current)
Output
• Electrical life: 100,000 or more switching operations
(switching frequency 1,200 operations/hour)
• Mechanical life: 50 million or more switching operations
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and
ם V) • Residual voltage: 1 V or less (at 100 mA source current)
(switching frequency 18,000 operations/hour)
0.4 V or less (at 16 mA source current)
Output operation
Short-circuit protection
Response time
Switchable either Detection-ON or Detection-OFF
Incorporated
20 ms or less (For EQ-50ⅪT depends on the setting timer period) 2 ms or less (For EQ-51ⅪT depends on the setting timer period)
Orange LED (lights up when the output is ON)
Operation indicator
Stability indicator
Distance adjuster
Sensing mode
Green LED (lights up under stable operating condition)
2-turn mechanical adjuster with indicator
Switchable either BGS or FGS function
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
Timer function
OFF-delay timer
OFF-delay timer
OFF-delay timer
OFF-delay timer
Automatic interference prevention function
Protection
Incorporated (Note 3)
IP67 (IEC)
Ambient temperature
Ambient humidity
Ambient illuminance
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Receiving element
Material
מ 20 to 55 ЊC מ 4 toם 131 ЊF (No dew condensation or icing allowed), Storage: מ 30 toם 70 ЊC מ 22 toם 158 ЊF 35 to 85 % RH, Storage: 35 to 85 % RH
Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face
2,000 V AC for one min. among supply terminals, non-supply metal parts and relay contact output terminals, 1,000 V AC for one min. between relay contacts
100 M , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Infrared LED (modulated)
2-segment photodiode
Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate
Screw-on terminal connection
Connection method
Cable
Suitable for round cable "9 to"11 mm "0.354 to "0.433 in
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable
Cable length
Weight
100 g approx.
85 g approx.
Accessory
Adjusting screwdriver: 1 pc.
Notes: 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m
0.328 ft, or more, away.
2) The adjustable range and the sensing range are specified for white non-glossy paper (200
ן 200 mm 7.874ן 7.874 in) as the object. 3) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to ‘Automatic interference function’ (p.8) of ‘PRECAUTIONS FOR PROPER USE’ for
details.
198
08/2005
EQ-500
I/O CIRCUIT AND WIRING DIAGRAMS
EQ-501(T)
EQ-502(T)
I/O circuit diagram
Terminal arrangement diagram
Terminal No.
1
2
Supply voltage
24 to 240 V AC
ע 10 % or
Multi-voltage
circuit
2
4
1
3
12 to 240 V DC
ע 10 % Output relay
S
3
4
Relay contact output
(1a)
Internal circuit
EQ-511(T)
EQ-512(T)
I/O circuit diagram
Terminal arrangement diagram
Terminal No.
D
ם V 1
4
3
2
ZD2
Tr2
Tr1
100 mA max.
2
4
1
3
Load
ם מ Output (PNP)
Load
12 to 24 V DC
ע 10 % Output (NPN)
100 mA max.
ZD1
0 V
Internal circuit
Users’ circuit
Symbols... D : Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1: NPN output transistor
Tr2: PNP output transistor
SENSING CHARACTERISTICS (TYPICAL)
EQ-501(T)
EQ-511(T)
Sensing fields
Correlation between material
• Setting distance: 1 m 3.281 ft
• Setting distance: 2.5 m 8.202 ft
(200
200 mm 7.874 7.874 in) and sensing range 4
13.123
White non-
glossy paper
Black non-glossy paper
Lightness: 5
White non-
glossy paper
Black non-glossy paper
Lightness: 5
2.5
8.202
1
3.281
3
9.843
200
ן 200 mm 2
6.562
7.874
ן 7.874 in These bars indicate the
0.5
Non-glossy paper
200
ן 200 mm 7.874
ן 7.874 in Non-glossy paper
sensing range with the
respective objects when
the distance adjuster is set
to a sensing range of 2.5 m
8.202 ft / 1 m 3.281 ft long,
respectively, with white
non-glossy paper.
1.640
2.5 m
1
⅐⅐⅐
⅐⅐⅐
8.202 ft
#
3.281
L
#
L
1
3.281
1 m
3.281 ft
Sensor
Sensor
0
0
0
20
10
0
10
20
0.787
20
10
0.394
Left
0
10
20
0.787
0.787
0.394
0.394
Right
0.787
0.394
Left
Center
Center
Right
Operating point ?(mm in)
Operating point ?(mm in)
Emitted beam
Correlation between color
Correlation between sensing object size
and sensing range
(200
200 mm 7.874 7.874 in non-glossy paper) and sensing range These bars indicate the
sensing range with the re-
spective colors when the
distance adjuster is set to a
Setting distance: 2.5 m 8.202 ft
"70 mm
2.5
"2.756 in
2.5
2.5
8.202
8.202
8.202
sensing range of 2.5
m
"56 mm
"2.205 in
8.202 ft / 1 m 3.281 ft long,
respectively, with white non-
glossy paper.
The sensing range also
varies depending on material.
2
6.562
2
6.562
This curve shows
the characteristics
with the maximum
sensing range set
to 2.5 m 8.202 ft,
with white non-
glossy paper
"42 mm
1.5
4.921
"1.654 in
White non-
glossy paper
"26 mm
"1.024 in
1
3.281
L
1
3.281
1
3.281
2.5 m
⅐⅐⅐
8.202 ft
"20mm
"0.787 in
0.5
1.640
1 m
⅐⅐⅐
3.281 ft
(200
7.874
200
7.874
ן 200 mm
7.874 in).
Sensor
100
0
ן 0
0
50
1.969
150
5.906
3.937
White non-glossy paper
side length a (mm in)
199
08/2005
EQ-500
SENSING CHARACTERISTICS (TYPICAL)
EQ-502(T)
EQ-512(T)
Sensing fields
Correlation between material
• Setting distance: 0.5 m 1.640 ft
(200
200 mm 7.874 7.874 in) and sensing range • Setting distance: 1 m 3.281 ft
0.8
2.625
White non-
glossy paper
White non-
glossy paper
Black non-glossy paper
Black non-glossy paper
Lightness: 5
Lightness: 5
1
3.281
)
)
1
3.281
)
f
f
0.6
1.969
f
200
7.874
Non-glossy paper
ן 200 mm
200
7.874
Non-glossy paper
ן 200 mm
These bars indicate the
sensing range with the
respective objects when
the distance adjuster is set
to a sensing range of 1 m
3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy paper.
0.4
ן 7.874 in
ן 7.874 in
1.312
0.5
0.5
1.640
1 m
1.640
⅐⅐⅐
⅐⅐⅐
3.281 ft
L
L
?
?
0.2
0.656
e
S
S
0.5 m
1.640 ft
Sensor
Sensor
0
0
0
20
10
0
10
0.394
20
0.787
20
10
0.394
Left
Operating point ?(mm in)
0
10
20
0.787
0.787
0.394
0.787
0.394
Left
Center
Right
Center
Right
Operating point ?(mm in)
Correlation between color
Emitted beam
Correlation between sensing object size
and sensing range
(200
200 mm 7.874 7.874 in non-glossy paper) and sensing range These bars indicate the
sensing range with the re-
spective colors when the
distance adjuster is set to a
sensing range of 1 m 3.281 ft
Setting distance: 1 m 3.281 ft
"26 mm
1
1
1
"1.024 in
3.281
3.281
3.281
/
0.5
m
1.640 ft long,
This curve shows
respectively, with white non-
glossy paper.
The sensing range also
varies depending on material.
the characteristics
with the maximum
sensing range set
"20 mm
"0.787 in
0.5
1.640
0.5
1.640
0.5
1.640
White non-
L
glossy paper
to
1
m
3.281 ft,
1 m
⅐⅐⅐
with white non-
glossy paper
3.281 ft
0.5 m
⅐⅐⅐
(200
7.874
ן 200 mm
7.874 in).
1.640 ft
Sensor
ן 0
0
50
1.969
100
3.937
150
5.906
200
7.874
White non-glossy paper
side length a (mm in)
PRECAUTIONS FOR PROPER USE
• When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid faulty operation.
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
<Incorrect>
<Correct>
Specular
face
Specular
face
M5 nut
Mounting
M5 (length 30 mm 1.181 in)
screw with washers
• The tightening torque
should be 0.8 N⅐m or
less.
Tilt
Sensor
mounting
blacket
MS-EQ5-01
(Optional)
• This product is not easily affected by the reflected light intensity
since this sensor is the adjustable range reflective type. When
the reflected light intensity is remarkably low, the sensing range
may be affected. In that case, mount the sensor, while checking
light-up of the stable indicator (green).
Care must be taken regarding the sensor mounting direction with
respect to the object’s direction of movement.
•
• The mounting screws of the terminal cover and display cover
should certainly be tightened to maintain water-resistance; the
tightening torque of the screws should be 0.3 to 0.5 N⅐m.
<Correct>
<Correct>
<Incorrect>
Automatic interference prevention function
• When the sensors are mounted closely, use them in the
interference prevented area, as shown below.
9.8343
6.5262
3.2181
3
9.843
Do not make the sensor
L mm in
or more
detect an object in this
direction because it may
2
Sensing object
6.562
Sensing object
Sensing object
cause
unstable
3.2181
0
Interference
Interference
prevented area
• When detecting a specular object (aluminum or copper foil, etc.)
or an object having a glossy surface or coating, please note that
there are cases when the object may not be detected due to a
change in angle, wrinkles on the object surface, etc.
prevented area
L mm in
or more
L mm in
or more
L mm in
or more
0
02.7087 14.5075 26.3062 80
3.15
Mounting interval L (mm in)
50 100 150 200 250
1.969 3.937 5.906 7.874 9.843
Mounting interval L (mm in)
• If a specular body is present in the background, faulty operation
may be caused due to a small change in the angle of the
background body. In that case, install the sensor at an inclination
and confirm the operation with the actual sensing object.
• Note that the detection may be unstable depending on the
mounting conditions or the sensing object to be used.
In the state that this product is mounted, be sure to check the
operation with the actual sensing object to be used.
200
08/2005
EQ-500
PRECAUTIONS FOR PROPER USE
Wiring
Part description
• Make sure that the power supply is off while wiring.
Stability indicator (Green)
• Check all wiring before applying power since incorrect wiring may
damage the internal circuit. Also, carefully tighten the terminal
screws so that the wires of adjacent terminals do not touch.
Distance adjuster (2-turn)
OFF-delay timer adjuster (Note 2)
• The mounting hole for the terminal cover fixing screws inclines
70 degrees to the terminal cover, as shown in the figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
Adjuster indicator
ON-delay timer adjuster (Note 2)
Operation mode switch (Note 1)
Operation indicator (Orange)
Screw for terminal cover fixing
Notes: 1) The operation mode switch of the DC-voltage type is the DIP
switch. Refer to ‘DC-voltage type’ of ‘Operation mode switch’
for details.
2) Incorporated on EQ-5ⅪT only.
Screwdriver
Operation mode switch
Multi-voltage type (L-ON / D-ON mode only)
• To maintain water-resistance, the cable should have an outer
diameter between "9 to "11 mm "0.354 to "0.433 in with a
smooth covering material that allows the attached conduit
connector to be securely tightened; the tightening torque of the
screw should be of 1.5 to 2.0 N⅐m.
Operation mode switch
Description
• Verify that the supply voltage variation is within the rating.
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the
frame ground (F.G.) terminal of the equipment to an actual ground.
Note: Turn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
• Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
• If an external surge voltage exceeding 4 kV is impressed (DC-
voltage type: 1 kV), the internal circuit will be damaged, and a
surge suppressing element should be used.
DC-voltage type
L-ON / D-ON mode
BGS / FGS mode
Timer mode
L
BGS
OFF
N.C.
D
• Prepare the cable end as shown below.
FGS
Timer ON
N.C.
Conduit connector construction and cabling
Not used
37 mm
1.457 in
Power supply
BGS / FGS function (DC-voltage type only)
Conduit connector
•
DC-voltage type sensor incorporates BGS / FGS function. Select
either the BGS or FGS function depending on the positions of the
background and sensing object.
BGS / FGS function is set with the operation mode switch.
Depends on a selection of either BGS or FGS function, the out-
put operation changes as follows.
Output
25 mm
0.984 in
Gland packing (Note)
Gland
•
Note: When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
Detectable range
• The size of conduit is M20
ן 1.5. • If pressure terminals are to be used, affix the connected
Setting distance
pressure terminals to a terminal (M3.5 screw).
Non-detectable area
Dimensions of the suitable crimp terminals
ON
(Unit: mm in)
L-ON
OFF
BGS
Round type
Y-shaped type
ON
D-ON
OFF
"3.6
22 0.866
22 0.866
"0.142
3.6 0.142
or more
ON
or less
or less
L-ON
or more
10 0.394
or less
10 0.394
or less
OFF
FGS
ON
7.5 0.295
or less
7 0.276
or less
7.5 0.295
or less
7 0.276
or less
D-ON
OFF
17 0.669
or less
(After crimping)
17 0.669
or less
(After crimping)
Note: Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25
ן 3.5 0.049ן 0.138. •
The tightening torque for the terminal screws should be 0.3 to 0.5 N⅐m.
201
08/2005
EQ-500
PRECAUTIONS FOR PROPER USE
Distance adjustment
Timer function (EQ-5ⅪT only)
• EQ-5ⅪT incorporates an OFF-delay timer, which is useful when
the response of the connected device is slow, etc., and an
ON-delay timer, which is useful for detecting objects that move
slowly, for example.
•
For DC-voltage type, be sure to set the BGS / FGS function before
distance adjustment. If the setting is done after the distance ad-
justment, the sensing area is changed.
• The OFF-delay and ON-delay timers can be used simultaneously.
• For DC-voltage type, set the DIP switch for the timer mode to
‘Timer ON’ side.
• Turn the distance adjuster gradually and lightly with the attached
adjusting screwdriver. Turning with excessive strength will cause
damage to the adjuster.
Multi-voltage type, DC-voltage type • BGS select
Time chart
Sensing
condition
Distance
Description
Step
adjuster
Operation
ON
Detection
Turn the distance adjuster fully counterclockwise
to the minimum sensing range position. (0.2 m
0.656 ft approx.)
normal operation
OFF
1
ON
Turn fully
Detection ON-delay
T
T
OFF
Please an object at the required distance from the
sensor, gradually turn the distance adjuster clock-
wise to determine point a, where the sensor
changes to the detecting state.
ON
Detection OFF-delay
T
T
T
T
2
3
4
OFF
ON
Detection ON / OFF-delay
Remove the object. Continue turning the adjuster
clockwise until the sensor enters the detecting
state again. Then turn the distance adjuster back
a little untill the sensor returns to the non-detec-
ting state, called point b .
OFF
ON
Non-detection
normal operation
OFF
ON
Non-detection ON-delay
Non-detection OFF-delay
T
T
T
If the sensor does not go into the detecting state
even if the adjuster is turned fully clockwise, point b
is regarded as the maximum position on the scale.
OFF
ON
T
T
OFF
Optimum
position
ON
Non-detection
ON / OFF-delay
The optimum position to stably detect objects is
the center point between a and b.
T
OFF
Timer period: T = 0.1 to 5 sec. (variable)
Stability indicator
DC-voltage type • FGS select
• Since the EQ-500 series uses a 2-segment photodiode as its
receiving element, and sensing is done based on the difference
in the incident beam angle of the reflected beam from the
sensing object, the output and the operation indicator (orange)
operate according to the object distance.
Furthermore, the stability indicator (green) shows the margin of
the setting distance.
Distance
adjuster
Description
Step
Turn the distance adjuster fully clockwise to the
maximum sensing range position. (2.5 m 8.202 ft
approx., 1.0 m 3.281 ft approx. for EQ-512Ⅺ)
1
Turn fully
Setting distance
In the state where the sensor detects the back-
ground, gradually turn the distance adjuster coun-
terclockwise, to determine point a where the
sensor changes to the non-detecting state.
2
3
4
Sensing object
Output (Operation indicator)
(In case of Detection-ON)
ON (Lights up)
OFF (Lights off)
Place an object at the required distance from the sensor,
turn the adjuster counterclockwise further until the sen-
sor goes into the non-detecting state again. Once enter-
ed, turn the adjuster backward a little until the sensor re-
turns to the detecting state, called point b .
Lights up
Lights off
Stability indicator
Stable operating
condition
Stable operating
condition
Unstable
If the sensor does not go into the non-detecting state
even if the adjuster is turned fully counterclockwise, point
b is regarded as the maximum position on the scale.
operating condition
Others
Optimum
position
• Take care that the sensor is not directly exposed to fluorescent
light from a rapid-starter lamp or a high frequency lighting device,
as it may affect the sensing performance.
The optimum position to stably detect objects is
the center point between a and b .
• Do not use during the initial transient time (50 ms) after the
power supply is switched on.
• This sensor is suitable for indoor use only.
• Its distance adjuster is mechanically operated. Do not drop; avoid
other shocks.
• Do not use this sensor in places having excessive vapor, dust,
etc., or where it may come in direct contact with water, or
corrosive gas.
• Take care that the sensor does not come in direct contact with
water, oil, grease or organic solvents, such as, thinner, etc.
• This sensor cannot be used in an environment containing
inflammable or explosive gases.
• Never disassemble or modify the sensor.
202
08/2005
EQ-500
DIMENSIONS (Unit: mm in)
EQ-501(T) EQ-502(T)
Sensor
EQ-511(T) EQ-512(T)
Assembly dimensions with sensor mounting bracket
MS-EQ5-01 (Optional) (Foot angled mounting)
Stability indicator (Green)
Distance adjuster (2-turn)
Operation mode switch (Note 1)
OFF-delay timer adjuster (Note 2)
6.5
0.256
(30.5)
(1.201)
Adjuster indicator
ON-delay timer adjuster (Note 2)
29
1.142
Operation indicator (Orange)
4
0.157
17.5
0.689
"6.5
6.5
"0.256
0.256
58
2.283
(10)
(10)
2
3-M5 nut seats
(on both sides)
(0.394)
(0.394)
26
1.024
68
2.677
0.079
Beam-
receiving part
2-M5 (length 30 1.181) screws
3-"5.1 "0.201
mounting holes
Center of beam-
emitting
(Center of sensing)
68 58
2.677 2.283
Center of beam-
emitting
(Center of sensing)
22
0.866
58
2.283
3.465
88
30
5
1.181
37
1.457
0.197
18
0.709
5
58
0.197
2.283
29
1.142
26
1.024
5
58
Notes: 1) The operation mode switch of the DC-voltage type is the DIP switch.
t 2
t 0.079
0.197
2.283
2) EQ-5ⅪT does not incorporate those.
78
3.071
203
08/2005
|